Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Table of Contents
maxLevel3

v6.3.1 Minor Software Updates (8/18/23 - 11/2/23)

08/18/23 - Fixed Packages > STRATUS Sheets Report Fields Issue

Fixed a Packages > STRATUS Sheets issue where Report Fields did not report correctly.

08/18/23 - Fixed Issue with API: /v1/package/{orderID}/report/{reportID}

Fixed an issue with the API: /v1/package/{orderID}/report/{reportID}

08/18/23 - Added CSG Trainers to Help Page

Added Frank Scott and Trent Leinenbach as contacts to company help pages to which they are assigned.

08/18/23 - Fixed Project Role Issue

Fixed a Project Role issue where a user with only Assemblies > Viewer permissions received an error.

08/18/23 - Fixed Assemblies Viewer Issue Reloading the Model

Fixed Assemblies Viewer issue where after switching to a different assembly within the same View, the 3D viewer reloaded the model and then displayed the assembly. With this fix, when the assembly within the same View, it will display almost instantly. If the newly selected assembly uses a different View, then the model will need to be reloaded before the assembly displays. For example:

  1. The SA-0001 Assembly displays in the 3D View.

    Image Removed

  2. Before this fix, after switching to the REV-001 Assembly the Powered by Autodesk logo would display indicating the model was being reloaded.

    Image Removed

08/19/23 - Fixed Reference Points for Grid Offset Not Same for Identical Parts

Prior to fix:

Image Removed

After fix:

Image Removed

08/19/23 - Fixed Hanger Rod Points Not Reporting Consistently

With this fix ITM hangers with 2 rods will report the coordinates for C2 and C3 in the correct order.

Image Removed

08/19/23 - Fixed Assemblies > Viewer: Assembly Dropdown Sort Order

Fixed an Assemblies > Viewer issue where the Assembly dropdown sorted assemblies randomly (below) rather than in the correct sort order.

Image Removed

08/23/23 - Removed the STRATUS Addin Update Required Button

Removed the STRATUS Addin Up To Date and Update Required buttons (below). These notifications and actions can no longer be used with the new WinGet installation process. See the Installation of GTP Software on Windows article for more information.

Image RemovedImage Removed

08/25/23 - Fixed a ZPL Report Issue Not Running on Selected Parts

Fixed a ZPL report issue where running a ZPL report using the Action toolbar, the report runs for the whole model instead of the visible or selected parts.

08/25/23 - Fixed a ZPL Report Issue with STRATUS.Field.*

Fixed a ZPL Report issue where STRATUS.Field.* fields no longer work on ZPL report labels.

08/25/23 - Fixed an Issue With Authoring Software is Always Right for Naming and Numbering

Fixed an issue under Admin > Company > Naming and Numbering > Numbering Rules > Authoring Software is Always Right > Part Filter. With this fix, when an Authoring Software is Always Right rule that incorporates a STRATUS.Filter that looks for a specific “Service Type” and parts match the filters, then it will not get an item number. For example:

  1. Create or edit a Filter that filters by ServiceType.

    Image Removed
  2. Add a Numbering Rule in the Authoring Software is Always Right section.

    Image Removed
  3. Add the Numbering Rule to a Numbering Scheme.

    Image Removed
  4. Prior to this fix, parts that should have been filtered out were receiving an item number.

    Image Removed
  5. With this fix, parts that should be filtered out are not receiving an item number.

    Image Removed

 

08/25/23 - Fixed an Assemblies Dashboard Issue Where Updating Field A did not Update Field B

Fixed an Assemblies Dashboard issue where updating STRATUS.Field A did not update STRATUS.Field B. For example:

  1. Configure 2 fields with one field referencing another field.

    Image Removed
  2. Add these fields to an Report where:

    1. Item Type = Assembly

    2. Assemblies Dashboard = checked

      Image Removed
  3. In the Assemblies Viewer, select the report. Enter a value in STRATUS.Field A. It should immediately update STRATUS.Field B.

    Image Removed

08/30/23 - Fixed Issue Switching to a Project from an Assembly

Fixed an issue using the Project drop-down to switch to a different Project while in the Assemblies > Viewer. In this case, after the new Project loaded, “All Models” was selected in the Models drop-down. Since STRATUS would not know which model, package, or assembly to selected, this switch often ended up in an error. With this fix, when the user changes to a new Project, instead of selecting All Models, the first model (alphabetic) will be selected and if the model has an assembly, the first assembly (alphabetic) will be selected. If the model does not have an assembly, the Assemblies > Dashboard will display.

08/31/23 - Added Preview and Download All Attachments Options from Dashboards

Added the ability to download one or All attachments from all Dashboards (Packages, Assemblies, and Containers).

Image Removed
  1. Attachments Note: The following file types can be attached:

    1. .pdf, .txt, .csv, .gif, .png, .jpg, .jpeg, .xls, .xlsx, .xlsm, .doc, .docx, .maj, .mp4, .rej, .zip, .zpl

  2. Date Attached - Displays the date the file was attached.

  3. Preview (image file types only) - In the drop-down dialog, the following image file image file types will display for Preview:

    1. .gif, .jpeg, .jpg, .png

  4. Preview Attachment - Click the Preview Attachment button to display in a separate window the attachment preview for certain file types including:

    1. .pcf, .pdf, .txt, .csv, .zpl, .gif, .jpeg, .jpg, .png

      Image Removed
    2. Preview is not available for: .xls, .xlsx, .xlsm, .doc, .docx, .maj, .mp4, .rej, .zip

    3. Click the Download button to download the attachment.

  5. Download Attachment

    1. To download a single file attachment, click its corresponding Download Attachment button. The file will download to your default downloads folder. There won’t be any prompt or confirmation. The file name syntax will be the:

      Image Removed
      1. Name of the attachment (Ex. REV-FR-0003)

      2. Date downloaded (Ex. 08-28-2023)

      3. Time stamp to make each download unique (Ex. 21-33-40)

      4. File type (Ex. pcf).

  6. Download All - Click the Download All button to download each individual file attachments associated with the selected Package, Assembly, or Container to your default download folder. The name of each file will follow the syntax as if the individual file’s Download Attachment (above) button was clicked.

  7. Download All (ZIP) - To download a single zip file with all of the attachments associated with the selected Package, Assembly, or Container to your default download folder, click the Download All (ZIP) button. The file name syntax will be the:

    Image Removed
    1. Name

      1. Package - Name of the first file in the attachment list

      2. Assembly - Name of the first file in the attachment list

      3. Container - Name of the Container

    2. Attachments

    3. Date downloaded (Ex. 08-28-2023)

    4. Time stamp to make each download unique (Ex. 21-29-21)

    5. File type (Ex. .zip)

09/05/23 - Fixed Sum Issue on Report

Fixed an issue where on the Packages > Viewer > Parts table where the report summed FeetInchFraction, but did not correctly calculate the fractions.

The Report had the following settings:

  • Merge Like Values = Yes

  • Aggregate = Sum

  • Format = FeetInchFraction

  • Precision = 2

The report now displays the correct value including the fraction.

Image Removed

09/06/23 - Fixed a Lighting Publish Issue

Fixed a Lighting publish issue.

09/07/23 - Fixed Assembly Parts Not Displaying in Non-Default View

When a model is be published with multiple views, and one of them is determined by the Autodesk viewer to be the default. The issue that was fixes occurred when an assembly was created in a non-default View, the part would not display in the Assemblies > Viewer. For example:

  1. The default view is Full Model

    Image Removed
  2. User A with permission (Ex. Project Admin) to change Views, changed the View (Ex. Top Half) and created an assembly.

  3. User B, opened the assembly and the default View was used instead of the View User A had created the assembly in so the parts were filtered out.

  4. With this fix the View correctly changed for the User B when the Assemblies > Viewer is opened.

    Image Removed

09/21/23 - Added Division Drop-down during Package Creation

Added to the Models > Viewer > Actions > Packages dialog the Division drop-down.

Image Removed

09/21/23 - Fixed Assemblies > Viewer Annotation Issue

Fixed an issue in the Assemblies > Viewer where after adding an Annotation Tag in Assembly A, then switching to Assembly B, the Annotation tag remained in the view. As a result, it is no longer necessary to refresh the Assembly B Viewer page to remove Annotation Tags placed on Assembly A.

09/21/23 - Fixed Assemblies > Viewer > STRATUS Sheet Property Display

Fixed an issue displaying the STRATUS.Assembly.TrackingStatusLogDivision property on the Assemblies > Viewer > STRATUS Sheet.

09/21/23 - Updated ZPL Report Availability

Under Admin > Company > Reports, ZPL reports can be created when the report Format is ZPL. The report will display in any of the checked Viewers (Assembly, Model, Package). For example, the Package ZPL report will be available in the Models > Viewer under Actions > Reports.

Image Removed

09/21/23 - Fixed a Dimensioning Issue

Fixed an issue under Assemblies > Viewer > Dimensioning, where dimensioning worked within Assembly A, but after switching to Assembly B, the snap point nodes did not display.

Image Removed

09/21/23 - Updated Extract Geometry

For STRATUS Flex users, on the Models > Dashboard, updated the Extract Geometry feature to extract models published in with the STRATUS Addin in 2022 or more recent versions. To use this feature:

  1. Go to the Models > Dashboard.

  2. Click the Extract Geometry button.

    Image Removed
    1. The message will display.

      Image Removed
    2. Click Ok.

  3. The icon will change to Processing.

    Image Removed

  4. Refresh the page. When complete the Completed icon will display.

    Image Removed
  5. If the process failed, the Failed, Retry? icon will display. Check that the model was published in 2022 or more recently. If the issues persists, submit at Service Desk ticket.

    Image Removed

09/21/23 - Updated Top Navigation to Specify the Package

With this update, STRATUS will recognize when users are working with a package and store the last opened or refreshed package as the active package. As a result, when the user clicks a link to an assembly, the active package will carryover and be selected in the Package drop-down. Otherwise, the Package will be set to Unspecified.

For example:

  1. The user is working in this Package and can click any of these assembly links.

    Image Removed

  2. The assembly will display in the Assemblies > Viewer and the Package drop-down will carryover.

    Image Removed

09/21/23 - Fixed an Issue Automatically Generating Package Reports

Fixed an issue automatically generating package reports. Known Issue: There is a known issue automatically generating Package Reports where the selected report’s Item Type is Master. This will be fixed in a future release.

See the article Generate on Tracking Status (Report) for more information.

10/02/23 - Fixed an Issue with Tracking Status “Applies to” (Part, Assembly, Package) Setting

Fixed an issue under Admin > Company > Tracking Statuses where the Applies to (Part, Assembly, Package) was not displayed or hidden in one of the Viewers or Dashboards when changing tracking status. The Applies to settings tell STRATUS that a particular tracking status can or can't be applied to a Part, Assembly, or Package.

Image Removed

10/02/23 - Fixed an Issue where Advanced Estimating Values Did Not Populate a New Package

Under Admin > Company > Package Categories, administrators can configure Advanced Estimating for Office, Purchasing, Shop, Field, and other User Data fields. While a package is being created, these values change dynamically as parts are selected for the package. An issue was fixed where these values did not populate the while the package was being created. See the Advanced Estimating article for more information.

10/02/23 - Fixed an Issue Displaying Assemblies Alphanumerically when Package Switched

Fixed an issue displaying assemblies alphanumerically when the Package is switched in the Assemblies > Viewer. In this example, after the Package was switched, 001 should display, not 002. See the Open Assembly article for more information.

Image Removed

10/02/23 - Fixed an Issue Limiting Assembly Drop-down to Selected Package

Fixed an issue where the Assembly drop-down displayed all packages and assemblies even when a specific package had been selected.

In the example below the issue is that a Package is selected yet all assemblies from different packages display.

Image Removed

With this fix, the list of assemblies are limited to those within the selected Package.

Image Removed

10/02/23 - Fixed an Issue with Remembering Show Selection

Fixed an issue on the Packages > Dashboard and Assemblies > Dashboard with remembering the user’s Show selection.

Image Removed

Fixed an issue for MAJ parts that contain links to the Part, Assembly, and Package that opens the QR Code for the link clicked.

For example:

  1. This newly generated MAJ opened in CAMduct consistently displays:

    1. Links #1 = Part QR Code

    2. Links #2 = Assembly QR Code

    3. Links #3 = Package QR Code

      Image Removed
  2. When clicked the QR Code Scanned page will display.

    Image Removed

10/11/23 - Fixed a Mobile Dropdown Scrolling Issue

Fixed a mobile (tables or ipad) issue scrolling in the Package and Assembly drop-downs in the viewers.

10/11/23 - Added API Parameter excludeNullAndEmpty

Added to the OpenAPI the optional excludeNullAndEmpty parameter to the following calls which provides a nice performance boost for API customers.

GET /v1/assembly/{id}/parts
GET /v1/model/{id}/parts
GET /v2/package/{id}/parts
GET /v1/part
GET /v1/part/{qrcode}
GET /v2/part/{id}

10/16/23 - Fixed Size of GTP Quick Pass QR Code

Increased the size of the GTP Quick Pass QR Code.

10/19/23 - Fixed STRATUS.Part.GridOffset Value Display

Fixed an issue for CADmep models where STRATUS.Part.GridOffset values did not display for CID 838. Below the values correctly display.

Image Removed

Table of Contents
maxLevel3

v6.3.1 Minor Software Updates (8/18/23 - 11/2/23)

08/18/23 - Fixed Packages > STRATUS Sheets Report Fields Issue

Fixed a Packages > STRATUS Sheets issue where Report Fields did not report correctly.

08/18/23 - Fixed Issue with API: /v1/package/{orderID}/report/{reportID}

Fixed an issue with the API: /v1/package/{orderID}/report/{reportID}

08/18/23 - Added CSG Trainers to Help Page

Added Frank Scott and Trent Leinenbach as contacts to company help pages to which they are assigned.

08/18/23 - Fixed Project Role Issue

Fixed a Project Role issue where a user with only Assemblies > Viewer permissions received an error.

08/18/23 - Fixed Assemblies Viewer Issue Reloading the Model

Fixed Assemblies Viewer issue where after switching to a different assembly within the same View, the 3D viewer reloaded the model and then displayed the assembly. With this fix, when the assembly within the same View, it will display almost instantly. If the newly selected assembly uses a different View, then the model will need to be reloaded before the assembly displays. For example:

  1. The SA-0001 Assembly displays in the 3D View.

    Image Added

  2. Before this fix, after switching to the REV-001 Assembly the Powered by Autodesk logo would display indicating the model was being reloaded.

    Image Added

08/19/23 - Fixed Reference Points for Grid Offset Not Same for Identical Parts

Prior to fix:

Image Added

After fix:

Image Added

08/19/23 - Fixed Hanger Rod Points Not Reporting Consistently

With this fix ITM hangers with 2 rods will report the coordinates for C2 and C3 in the correct order.

Image Added

08/19/23 - Fixed Assemblies > Viewer: Assembly Dropdown Sort Order

Fixed an Assemblies > Viewer issue where the Assembly dropdown sorted assemblies randomly (below) rather than in the correct sort order.

Image Added

08/23/23 - Removed the STRATUS Addin Update Required Button

Removed the STRATUS Addin Up To Date and Update Required buttons (below). These notifications and actions can no longer be used with the new WinGet installation process. See the Installation of GTP Software on Windows article for more information.

Image AddedImage Added

08/25/23 - Fixed a ZPL Report Issue Not Running on Selected Parts

Fixed a ZPL report issue where running a ZPL report using the Action toolbar, the report runs for the whole model instead of the visible or selected parts.

08/25/23 - Fixed a ZPL Report Issue with STRATUS.Field.*

Fixed a ZPL Report issue where STRATUS.Field.* fields no longer work on ZPL report labels.

08/25/23 - Fixed an Issue With Authoring Software is Always Right for Naming and Numbering

Fixed an issue under Admin > Company > Naming and Numbering > Numbering Rules > Authoring Software is Always Right > Part Filter. With this fix, when an Authoring Software is Always Right rule that incorporates a STRATUS.Filter that looks for a specific “Service Type” and parts match the filters, then it will not get an item number. For example:

  1. Create or edit a Filter that filters by ServiceType.

    Image Added
  2. Add a Numbering Rule in the Authoring Software is Always Right section.

    Image Added
  3. Add the Numbering Rule to a Numbering Scheme.

    Image Added
  4. Prior to this fix, parts that should have been filtered out were receiving an item number.

    Image Added
  5. With this fix, parts that should be filtered out are not receiving an item number.

    Image Added

 

08/25/23 - Fixed an Assemblies Dashboard Issue Where Updating Field A did not Update Field B

Fixed an Assemblies Dashboard issue where updating STRATUS.Field A did not update STRATUS.Field B. For example:

  1. Configure 2 fields with one field referencing another field.

    Image Added
  2. Add these fields to an Report where:

    1. Item Type = Assembly

    2. Assemblies Dashboard = checked

      Image Added
  3. In the Assemblies Viewer, select the report. Enter a value in STRATUS.Field A. It should immediately update STRATUS.Field B.

    Image Added

08/30/23 - Fixed Issue Switching to a Project from an Assembly

Fixed an issue using the Project drop-down to switch to a different Project while in the Assemblies > Viewer. In this case, after the new Project loaded, “All Models” was selected in the Models drop-down. Since STRATUS would not know which model, package, or assembly to selected, this switch often ended up in an error. With this fix, when the user changes to a new Project, instead of selecting All Models, the first model (alphabetic) will be selected and if the model has an assembly, the first assembly (alphabetic) will be selected. If the model does not have an assembly, the Assemblies > Dashboard will display.

08/31/23 - Added Preview and Download All Attachments Options from Dashboards

Added the ability to download one or All attachments from all Dashboards (Packages, Assemblies, and Containers).

Image Added
  1. Attachments Note: The following file types can be attached:

    1. .pdf, .txt, .csv, .gif, .png, .jpg, .jpeg, .xls, .xlsx, .xlsm, .doc, .docx, .maj, .mp4, .rej, .zip, .zpl

  2. Date Attached - Displays the date the file was attached.

  3. Preview (image file types only) - In the drop-down dialog, the following image file image file types will display for Preview:

    1. .gif, .jpeg, .jpg, .png

  4. Preview Attachment - Click the Preview Attachment button to display in a separate window the attachment preview for certain file types including:

    1. .pcf, .pdf, .txt, .csv, .zpl, .gif, .jpeg, .jpg, .png

      Image Added
    2. Preview is not available for: .xls, .xlsx, .xlsm, .doc, .docx, .maj, .mp4, .rej, .zip

    3. Click the Download button to download the attachment.

  5. Download Attachment

    1. To download a single file attachment, click its corresponding Download Attachment button. The file will download to your default downloads folder. There won’t be any prompt or confirmation. The file name syntax will be the:

      Image Added
      1. Name of the attachment (Ex. REV-FR-0003)

      2. Date downloaded (Ex. 08-28-2023)

      3. Time stamp to make each download unique (Ex. 21-33-40)

      4. File type (Ex. pcf).

  6. Download All - Click the Download All button to download each individual file attachments associated with the selected Package, Assembly, or Container to your default download folder. The name of each file will follow the syntax as if the individual file’s Download Attachment (above) button was clicked.

  7. Download All (ZIP) - To download a single zip file with all of the attachments associated with the selected Package, Assembly, or Container to your default download folder, click the Download All (ZIP) button. The file name syntax will be the:

    Image Added
    1. Name

      1. Package - Name of the first file in the attachment list

      2. Assembly - Name of the first file in the attachment list

      3. Container - Name of the Container

    2. Attachments

    3. Date downloaded (Ex. 08-28-2023)

    4. Time stamp to make each download unique (Ex. 21-29-21)

    5. File type (Ex. .zip)

09/05/23 - Fixed Sum Issue on Report

Fixed an issue where on the Packages > Viewer > Parts table where the report summed FeetInchFraction, but did not correctly calculate the fractions.

The Report had the following settings:

  • Merge Like Values = Yes

  • Aggregate = Sum

  • Format = FeetInchFraction

  • Precision = 2

The report now displays the correct value including the fraction.

Image Added

09/06/23 - Fixed a Lighting Publish Issue

Fixed a Lighting publish issue.

09/07/23 - Fixed Assembly Parts Not Displaying in Non-Default View

When a model is be published with multiple views, and one of them is determined by the Autodesk viewer to be the default. The issue that was fixes occurred when an assembly was created in a non-default View, the part would not display in the Assemblies > Viewer. For example:

  1. The default view is Full Model

    Image Added
  2. User A with permission (Ex. Project Admin) to change Views, changed the View (Ex. Top Half) and created an assembly.

  3. User B, opened the assembly and the default View was used instead of the View User A had created the assembly in so the parts were filtered out.

  4. With this fix the View correctly changed for the User B when the Assemblies > Viewer is opened.

    Image Added

09/21/23 - Added Division Drop-down during Package Creation

Added to the Models > Viewer > Actions > Packages dialog the Division drop-down.

Image Added

09/21/23 - Fixed Assemblies > Viewer Annotation Issue

Fixed an issue in the Assemblies > Viewer where after adding an Annotation Tag in Assembly A, then switching to Assembly B, the Annotation tag remained in the view. As a result, it is no longer necessary to refresh the Assembly B Viewer page to remove Annotation Tags placed on Assembly A.

09/21/23 - Fixed Assemblies > Viewer > STRATUS Sheet Property Display

Fixed an issue displaying the STRATUS.Assembly.TrackingStatusLogDivision property on the Assemblies > Viewer > STRATUS Sheet.

09/21/23 - Updated ZPL Report Availability

Under Admin > Company > Reports, ZPL reports can be created when the report Format is ZPL. The report will display in any of the checked Viewers (Assembly, Model, Package). For example, the Package ZPL report will be available in the Models > Viewer under Actions > Reports.

Image Added

09/21/23 - Fixed a Dimensioning Issue

Fixed an issue under Assemblies > Viewer > Dimensioning, where dimensioning worked within Assembly A, but after switching to Assembly B, the snap point nodes did not display.

Image Added

09/21/23 - Updated Extract Geometry

For STRATUS Flex users, on the Models > Dashboard, updated the Extract Geometry feature to extract models published in with the STRATUS Addin in 2022 or more recent versions. To use this feature:

  1. Go to the Models > Dashboard.

  2. Click the Extract Geometry button.

    Image Added
    1. The message will display.

      Image Added
    2. Click Ok.

  3. The icon will change to Processing.

    Image Added

  4. Refresh the page. When complete the Completed icon will display.

    Image Added
  5. If the process failed, the Failed, Retry? icon will display. Check that the model was published in 2022 or more recently. If the issues persists, submit at Service Desk ticket.

    Image Added

09/21/23 - Updated Top Navigation to Specify the Package

With this update, STRATUS will recognize when users are working with a package and store the last opened or refreshed package as the active package. As a result, when the user clicks a link to an assembly, the active package will carryover and be selected in the Package drop-down. Otherwise, the Package will be set to Unspecified.

For example:

  1. The user is working in this Package and can click any of these assembly links.

    Image Added

  2. The assembly will display in the Assemblies > Viewer and the Package drop-down will carryover.

    Image Added

09/21/23 - Fixed an Issue Automatically Generating Package Reports

Fixed an issue automatically generating package reports. Known Issue: There is a known issue automatically generating Package Reports where the selected report’s Item Type is Master. This will be fixed in a future release.

See the article Generate on Tracking Status (Report) for more information.

10/02/23 - Fixed an Issue with Tracking Status “Applies to” (Part, Assembly, Package) Setting

Fixed an issue under Admin > Company > Tracking Statuses where the Applies to (Part, Assembly, Package) was not displayed or hidden in one of the Viewers or Dashboards when changing tracking status. The Applies to settings tell STRATUS that a particular tracking status can or can't be applied to a Part, Assembly, or Package.

Image Added

10/02/23 - Fixed an Issue where Advanced Estimating Values Did Not Populate a New Package

Under Admin > Company > Package Categories, administrators can configure Advanced Estimating for Office, Purchasing, Shop, Field, and other User Data fields. While a package is being created, these values change dynamically as parts are selected for the package. An issue was fixed where these values did not populate the while the package was being created. See the Advanced Estimating article for more information.

10/02/23 - Fixed an Issue Displaying Assemblies Alphanumerically when Package Switched

Fixed an issue displaying assemblies alphanumerically when the Package is switched in the Assemblies > Viewer. In this example, after the Package was switched, 001 should display, not 002. See the Open Assembly article for more information.

Image Added

10/02/23 - Fixed an Issue Limiting Assembly Drop-down to Selected Package

Fixed an issue where the Assembly drop-down displayed all packages and assemblies even when a specific package had been selected.

In the example below the issue is that a Package is selected yet all assemblies from different packages display.

Image Added

With this fix, the list of assemblies are limited to those within the selected Package.

Image Added

10/02/23 - Fixed an Issue with Remembering Show Selection

Fixed an issue on the Packages > Dashboard and Assemblies > Dashboard with remembering the user’s Show selection.

Image Added

Fixed an issue for MAJ parts that contain links to the Part, Assembly, and Package that opens the QR Code for the link clicked.

For example:

  1. This newly generated MAJ opened in CAMduct consistently displays:

    1. Links #1 = Part QR Code

    2. Links #2 = Assembly QR Code

    3. Links #3 = Package QR Code

      Image Added
  2. When clicked the QR Code Scanned page will display.

    Image Added

10/11/23 - Fixed a Mobile Dropdown Scrolling Issue

Fixed a mobile (tables or ipad) issue scrolling in the Package and Assembly drop-downs in the viewers.

10/11/23 - Added API Parameter excludeNullAndEmpty

Added to the OpenAPI the optional excludeNullAndEmpty parameter to the following calls which provides a nice performance boost for API customers.

GET /v1/assembly/{id}/parts
GET /v1/model/{id}/parts
GET /v2/package/{id}/parts
GET /v1/part
GET /v1/part/{qrcode}
GET /v2/part/{id}

10/16/23 - Fixed Size of GTP Quick Pass QR Code

Increased the size of the GTP Quick Pass QR Code.

10/19/23 - Fixed STRATUS.Part.GridOffset Value Display

Fixed an issue for CADmep models where STRATUS.Part.GridOffset values did not display for CID 838. Below the values correctly display.

Image Added

10/20/23 - Fixed Date Picker on Assemblies Viewer

Fixed an issue on the Assemblies Viewer where the Date Picker did not display when a Date field was used in either the Report Field or the Field.

The date field can be referenced in 2 ways:

  1. The date field can be referenced in the Report Field Format.

    1. Configure Report and Report Field where:

      1. Item Type = Part

      2. Assembly Viewer = Checked

      3. Format = Date

        Image Added
    2. Configure referenced Field (Ex. STRATUS.Field.DateTest) where:

      1. Data Type = String

      2. Expression = References one of the assembly’s part properties (Ex. EquipmentTag).

        Image Added

  2. The date field can be referenced in the Field Data Type.

    1. Configure Report and Report Field where:

      1. Item Type = Part

      2. Assembly Viewer = Checked

      3. Format = String

      Image Added
    2. Configure referenced Field (Ex. STRATUS.Field.DateTest) where:

      1. Data Type = Date

      2. Expression = References one of the assembly’s part properties (Ex. EquipmentTag).

        Image Added

  3. For either configuration option, run the Report. The field is editable and pops up the date picker.

    Image Added