Local Settings




The local settings are stored in a file that is located on and specific to your computer.



Automatic Conduit Run Cleanup

When Automatic Conduit Run Cleanup is enabled, the Conduit Run Cleanup command is executed behind the scene every time a conduit run or individual part is modified in Revit. This ensures the parameter values are always kept in sync across all parts of the conduit run. If disabled, the Conduit Run Cleanup command can always be run manually by simply clicking the button in the ribbon menu.

On larger projects, running the cleanup command the first time can take a while to complete. A progress indicator is provided. Once complete and the project is saved, incremental cleanup using the automatic mode is the best way to keep parameter values in sync.

Fix Conduit Run After Change or Reapply Type

The Change Type and Reapply Type commands in Revit are known to lose conduit run data. By enabling this feature, the conduit will be automatically fixed following these commands.

Automatic Electrical Schematic Updates

This option enables the electrical schematic representation of the feeder schedule to be automatically updated and reconciled as changes are made to the Revit model. If disabled, the user must manually change the selected root node or reload the feeder schedule to force model reconciliation to be performed.

Node Detection

This option enables automatic detection of Run ID, Origin, and Destination data based on geometric proximity of conduit run endpoints to recognized equipment in the model.

Automatic Wire Pull Calculations

This option enables the wire pull calculations to be automatically updated as changes are made to the Revit model. If disabled, the user must manually refresh the wire pull calculations.

Warn About Run ID Changes

This option enables a special warning message anytime the feeder schedule configured Run ID parameter (if specified) value is changed by the conduit run cleanup when conduit is modified in the model.

Deactivate License

The deactivate license button allows a user to uninstall the current license from the computer. Once completed, the software will become disabled and require reactivation for this computer. The released license may be activated on a different computer.

The deactivate license feature can be used to essentially check-in a license to make it available for a different computer to check-out.